HT208D, AC/DC Digital Clamp Meter True-RMS Multimeter

Price:
US$109.15
DM-HT208D
In stock
+
Add to wish list

The HT208D is a digital clamp meter and multimeter. It carries all the functionality that you expect from a handheld multimeter and is also able to detect current without the hassle of having to connect and disconnect wires back and forth. 

This is a dual impedance true RMS digital multimeter integrating a variety of measurements like AC/DC voltage, AC/DC current, frequency, duty ratio, resistance, capacitance, temperature, diode, continuity, NCV, VFD, inrush current, etc. And there are more functions like last data hold, flashlight, Max./Min./Relative value, Celsius/Fahrenheit degree, and zero key.

Features

  • CLAMP MULTIMETER: Measures inrush current, VFD current/voltage, AC/DC current, AC/DC voltage, frequency, duty ratio, resistance, continuity, diode, capacitance, temperature, non-contact AC voltage (NCV) detection, and live detection.
  • WIDE OPENING JAW: Opening jaw capacity is 40mm, wide enough to measure without disturbing the circuit.
  • LOUD BEEP: NCV sensor send out audible and visual alarm once received electromagnetic signal.
  • MORE FUNCTIONS: Features data hold, flashlight, low battery display, Celsius/Fahrenheit degree, Max./Min./Relative value, and Zero(reset) key.
  • SAFE TO USE: Designed and conforms to IEC61010-1, CAT III 1000V, safe and reliable.
  • AUTO-OFF: Auto power off within 15 minutes if there is no operation, helps conserve the battery.
  • MULTI TESTER: Comes with 2 test leads and a thermocouple to be used as a multitester.

Specifications

General Specifications
Brand HABOTEST Item Size 24*8*4.5cm/9.44*3.14*1.77in
Material ABS Item Weight 311g/10.97oz
Colour Black and Red Package Size 27.5*13.5*5.5cm/10.82*5.31*2.16in
Battery 2 x 1.5V alkaline battery Package Weight 620g/21.86oz

Function Range Resolution Accuracy
DC Current 60A 0.01A ±(2.5%reading+8)
600A 0.1A
1000A 1A
AC Current 60A 0.01A ±(2.5%reading+8)
VFD: ±(5.0%reading+10)
INRUSH: ±(5.0%reading+10)
600A 0.1A
1000A 1A
DC Voltage 600mV 0.1mV ±(0.5%reading+5)
6V 0.001V
60V 0.01V
600V 0.1V
1000V 1V ±(0.8%reading+5)
AC Voltage 600mV 0.1mV ±(0.8%reading+5)
6V 0.001V
60V 0.01V
600V 0.1V
750V 1V ±(0.8%reading+5)
VFD (750V) 0.1V ±(2.0%reading+5)
Resistance 600Ω 0.1Ω ±(1.0%reading+5)
6kΩ 0.001kΩ
60kΩ 0.01kΩ
600kΩ 0.1kΩ
6MΩ 0.001MΩ
60MΩ 0.01MΩ
Diode It displays the approximate forward voltage value of the diode. Forward DC current is about 1.5mA
Reverse DC voltage is about 3V
Overload protection: 250V
Continuity if the resistance >30Ω, the buzzer and the LED light will go off Test Voltage Approx. 1V
Overload protection: 250V
Capacitance 10nF 0.001nF  ±(4.0%reading+5)
100nF 0.01nF
1000nF 0.1nF
10μF 0.001μF
100μF 0.01μF
1000μF 0.1μF
10mF 0.001mF
100mF 0.01mF ±(5.0%reading+10)
Frequency/Duty Ratio 10Hz 0.001Hz ±(1.0%reading+3)
100Hz 0.01Hz
1000Hz 0.1Hz
10kHz 0.001kHz
100kHz 0.01kHz
1000kHz 0.1kHz
10MHz 0.001MHz ±(3.0%reading+3)
1~99% 0.1%
Temperature -20℃~0℃ 1℃ ±3℃
0℃~400℃ ±1.0% or ±2℃
400℃~1000℃ ±2.0%
-4℉~32℉ 1℉ ±6℉
32℉~752℉ ±1.0% or 4℉
752℉~1832℉ ±2.0%

Shipping List

  • 1 * Digital Clamp Meter
  • 1 * Thermocouple
  • 2 * Test Lead
  • 1 * User Manual(English)
Notice for California Residents: Warning symbolWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov