Battery Pack Input Voltage Charging Voltage (set by R1) R1 Value (kΩ) Charging Current (set by RCS) LED Indicators Key Features
1S (1 Cell) 4.5 - 5.5V DC 1.35-7V 10.0 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
2S (2 Cell) 4.5 - 5.5V DC 2.7-3.4V 10.0 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
3S (3 Cell) 4.5 - 5.5V DC 4.05-5.1V 20.0 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
4S (4 Cell) 4.5 - 5.5V DC 5.7-6.8V 30.0 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
5S (5 Cell) 4.5 - 5.5V DC 6.75-8.5V 40.2 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
6S (6 Cell) 4.5 - 5.5V DC 8.1-10.2V 49.9 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
7S (7 Cell) 4.5 - 5.5V DC 9.45-11.9V 60.4 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance
8S (8 Cell) 4.5 - 5.5V DC 10.8-13.6V 69.8 Pre-charge: ~100 mA
Fast charge: ~250 mA (RCS 1–10 Ω, larger = lower current)
ON: powered, not charging
Slow Flash (~1 Hz): charging
Fast Flash (~10 Hz): short/wrong pack
OFF: fully charged
Zero-volt activation, short-circuit protection, automatic stop, safe trickle maintenance

Charging Process

  • Battery Detection – Detects insertion and verifies pack voltage.
  • Pre-Charge – If cell < 1 V → trickle charge (~100 mA) until safe.
  • Fast Charge – Constant ~250 mA until near full (~1.35 V/cell).
  • ΔV Cutoff / Top-Up – Automatically stops or enters trickle to prevent overcharge.
  • Trickle Mode – Maintains charge, compensates for self-discharge.
  • Auto Reset – When battery is removed, charger resets for next use.

Protection Features

  • Short-Circuit Protection: Shuts down safely if BAT+ and BAT– are shorted.
  • Zero-Volt Activation: Revives deeply discharged packs safely.
  • Overvoltage Cutoff: Stops charging if per-cell > 1.35 V.
  • Auto Pack Verification: No charging if pack voltage is out of range.

Module Details

  • Input Pins: VIN / GND
  • Output Pins: BAT+ / BAT–
  • Set Resistors:
    • R1 → sets charging voltage (per pack size).
    • RCS → sets charging current (1–10 Ω recommended).
  • LED Indicators: Multi-status (power, charge, short, full).
  • Weight: ~2.00 g
  • Note: Output voltage cannot be measured with a multimeter without a battery; must use oscilloscope.