5-30VDC Trigger Cycle Delay Switch Module with Real Time Clock (RTC)
This versatile timer can be programmed from 0.1 seconds to 999 minutes ,a four-by-seven segment displays the time in 0.1 second, second, r minute. It has a wide power supply 5.0V ~ 60V, a mode can be defined for several periods, can reach 5 periods and features a buzzer alarm function.
Introduction mode:
OPE: relay closing time, CLE: relay deactivation time
Period of time: PE-1 ~ PE-5 5 periods (OPE to CLE is a period)
shielding function
P-1: The relay closes or pulses every day to the OPE time point, and the relay is deactivated or pulses to the time point CLE.
P-2: Set the day on the OPE time point when the relay is closed or an output pulse, on the CLE time point when the relay disconnects / or emits a pulse.
P-3: Set the date of the month on the OPE time point when the relay is closed or on an output pulse, on the WK time point when the relay is off or on an output pulse.
P-4: Set the date 1 on the date 2, start every day at the local OPE time, stop until the local time CLE, relay action or output pulse3
P-5: As with P-4, only the month can not be set.
How to set the time?
In the time to run the interface, press the DOWN button for a moment:
Step 1: Select the period: PE-1 ~ PE-5 Press UP and DOWN to select;
Step 2: Press the SET button to select the mode: P-1 ~ P-5 (Set this period to the corresponding mode) by pressing the UP and DOWN buttons. ("----" means block this period)
Note: Each period can be repeated from "----", P-1 to P-5, one of the options; For example, you can leave five periods simultaneously in P-1 mode or leave period 1 in P-1 mode, period 2 in P-2 mode, and so on.
Step 3: Once the mode selection is complete, press the SET key to enter the period setting interface, set the interface in the period, then press the SET key to change the setting, start time "OPE", end "CLE" point, "dAE" date information;
Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to validate, automatically check if the settings are legal, legal to save the settings, return to the interface execution time ; if the parameter is incorrect, callback "ERR" (for example, stop time or Date <= start time or date), return to the parameter setting interface;
Additional features: Each "period" can be set individually
In the specific parameterization interface (after the second step), press the STOP key to change the output mode:
OUT1: Start time turns on relay, end time is off relay
OUT2: emits a 1S pulse for start or end
In the specific parameterization interface (after the second step), press the STOP key for a moment to change the ringing mode:
BLL0: Disable the ringtone
BLL1: activation of the ring
Note: When the bell rings, press any button to stop the ring.
Extension of the STOP key function:
Relay activation mode:
1. ON: activate the relay;
2. OFF: Do not activate the relay, it is always off;
Press the STOP button on the time display interface to toggle between ON and OFF, the current status flashes, and then you return to the main interface. (This function is the emergency stop function, press once to close the closed relay)
Once the relay is deactivated, the product can be used as an alarm clock.
Standby:
1. Standby mode C-P: within five minutes, without any operation, the digital tube automatically closes the display, the normal operation of the program;
2. Normal mode O-d: the digital tube is always open;
Press the STOP button for a moment after 2 seconds to release, to reach the C-P and O-d status of the switch, the current status will flash, then return to the main interface.