FRM03 3 Relay Timer Module
- This three relay timer can be set to control three timer output channels with up to 18 functions.
- Each relay can control 10 amps @250VAC or 10 amps @30VDC.
- Has a wide input power range of 8-32VDC and four input trigger channels X1, X2, X3.
- Timer can be independently programmed or used in conjunction with trigger pulse inputs.
- All settings are automatically saved when power is turned off.
- Delay times can be set from 0.1 second to 270 hours.
Specifications:
- Number of Relays: 3
- Relays 10A @250VAC /10A @30VDC
- Users can set and select the following through keystrokes and display one of 18 functions.
- Function parameters can be set and saved.
- Time parameters can be set from 0.1 seconds to 270 hours.
- Function 1-8 is self-starting when it is powered on.
- Function 9-18 needs a high (or low) 20 ms or longer pulse signal to trigger the start.
- Function 9 is self-locking mode. Function 10 is level control mode.
- The X port mentioned in the following text can be any of the X1-X3 ports.
Programming
- The four buttons SET, SW1, NUM+, NUM- are used to program the timer.
- They can be pushed momentarily (<1 second) or longer (>1 second) to enter different modes.
- Refer to the MD, T1, T2, NX indicators beside the display for the programming step.
- MD indicates program mode.
- T1 shows Delay Time T1, T2 shows Delay Time T2 setting in seconds
- NX has different meanings depending on the function including time base definition and number of cycles.
- The SET button steps through the program steps and stores the entry.
- The SW1 button steps through the display digits for relay number, delay times and function number.
- The NUM+ and NUM- changes the digits.
- Programs are retained after power off until a new program is entered.
User Manual Link:
https://cdn.instructables.com/ORIG/FKQ/BV7D/IUHMS1GV/FKQBV7DIUHMS1GV.pdf